{"id":1407,"date":"2023-10-23T09:30:45","date_gmt":"2023-10-23T01:30:45","guid":{"rendered":"https:\/\/www.dxfluidics.com\/?p=1407"},"modified":"2025-02-24T10:24:08","modified_gmt":"2025-02-24T02:24:08","slug":"%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87","status":"publish","type":"post","link":"https:\/\/www.dxfluidics.com\/en\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/","title":{"rendered":"organoid chip"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Dual Runner Designed Organ Chips<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An advanced organoid chip technology inspired by the concept of organoid chips, it consists of two independent channels that support 2D and 3D cell cultures to mimic physiological environments, especially in studying the effects of fluid shear stress on gene expression in blood vessels.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-02.png\" alt=\"\" class=\"wp-image-1409\" style=\"aspect-ratio:1.5;width:414px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Organoid Chip Flow Path Parameters<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chip material: PDMS<\/li>\n\n\n\n<li>Channel: Height 375um, Width 1.5mm, Length 43mm, Volume 24uL<\/li>\n\n\n\n<li>Customization: Different runner widths and types of organoid chips can be customized.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Application Areas\uff1a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cell adhesion processes on the vascular endothelium and related vascular studies<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">microfluidic organ chip<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A very comprehensive microfluidic organochip, unique in its ability to connect culture wells and microfluidic channels through a porous membrane, which facilitates complex culture setups.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This technology allows the use of an automated cell culture substance replacement system to perform air-liquid interface (ALI) experiments on 2D and 3D cells including, but not limited to, epithelial cell cultures, toxicity testing, and uptake testing.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"translation-block\"><strong>Highly versatile microfluidic organoids:<\/strong> Known for their versatility, they cleverly connect culture wells to microfluidic channels through porous membranes, offering more possibilities for culture configurations for research.<\/li>\n\n\n\n<li class=\"translation-block\"><strong>Gas-liquid interface (ALI) experiments:<\/strong> Microfluidic organoids are unique in that they make gas-liquid interface (ALI) experiments easy. Such experiments include simulations of cell exposure to gaseous environments such as epithelial cell cultures as well as various tests such as toxicity and uptake.<\/li>\n\n\n\n<li class=\"translation-block\"><strong>Automated Cell Culture Substance Replacement System<\/strong>: OrganoChips provide an automated cell culture substance replacement system that allows you to easily manage changes in culture substances during the course of an experiment, ensuring accuracy and reproducibility.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In summary, organoids provide researchers with a wide range of experimental configuration options and are particularly suitable for air-liquid interface (ALI) experiments, providing a convenient solution for a variety of cell cultures and tests.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-01.png\" alt=\"\" class=\"wp-image-1411\" style=\"aspect-ratio:1.5;width:462px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Organ Chip Runner Technical Parameters<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Chip material: PDMS<\/li>\n\n\n\n<li>Channel: Height 375um, Width 1.5mm, Length 43mm, Volume 24uL<\/li>\n\n\n\n<li>Customization: Different runner widths and types of organoid chips can be customized.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Application Areas\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In vitro models of the immune system, in vitro models of cancer metastasis, and microarray models of the skin and gut<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contact Information<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"569\" height=\"284\" src=\"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/image-28.png\" alt=\"\" class=\"wp-image-1381\"\/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u53cc\u6d41\u9053\u8bbe\u8ba1\u7c7b\u5668\u5b98\u82af\u7247 \u4e00\u6b3e\u5148\u8fdb\u7684\u7c7b\u5668\u5b98\u82af\u7247\u6280\u672f\uff0c\u5176\u8bbe\u8ba1\u7075\u611f\u6765\u6e90\u4e8e\u7c7b\u5668\u5b98\u82af\u7247\u7684\u7406\u5ff5\uff0c\u5b83\u7531\u4e24\u4e2a\u72ec\u7acb\u901a\u9053\u7ec4\u6210\uff0c\u652f\u63012 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1408,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_crdt_document":"","footnotes":""},"categories":[13],"tags":[],"class_list":["post-1407","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-organ-chip"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dxfluidics.com\/en\/product\/microfluidic-chip\/organ-chip\/1407\/\u7c7b\u5668\u5b98\u82af\u7247\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7\" \/>\n<meta property=\"og:description\" content=\"\u53cc\u6d41\u9053\u8bbe\u8ba1\u7c7b\u5668\u5b98\u82af\u7247 \u4e00\u6b3e\u5148\u8fdb\u7684\u7c7b\u5668\u5b98\u82af\u7247\u6280\u672f\uff0c\u5176\u8bbe\u8ba1\u7075\u611f\u6765\u6e90\u4e8e\u7c7b\u5668\u5b98\u82af\u7247\u7684\u7406\u5ff5\uff0c\u5b83\u7531\u4e24\u4e2a\u72ec\u7acb\u901a\u9053\u7ec4\u6210\uff0c\u652f\u63012 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dxfluidics.com\/en\/product\/microfluidic-chip\/organ-chip\/1407\/\u7c7b\u5668\u5b98\u82af\u7247\/\" \/>\n<meta property=\"og:site_name\" content=\"\u9876\u65ed\u5fae\u63a7\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-23T01:30:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-24T02:24:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"dxfluidics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"dxfluidics\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/\"},\"author\":{\"name\":\"dxfluidics\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#\\\/schema\\\/person\\\/255c77b7dba4089ee0f61539d31afbf7\"},\"headline\":\"\u7c7b\u5668\u5b98\u82af\u7247\",\"datePublished\":\"2023-10-23T01:30:45+00:00\",\"dateModified\":\"2025-02-24T02:24:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/\"},\"wordCount\":18,\"publisher\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png\",\"articleSection\":[\"\u7ec6\u80de\u82af\u7247\\\/\u5668\u5b98\u82af\u7247\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/\",\"name\":\"\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png\",\"datePublished\":\"2023-10-23T01:30:45+00:00\",\"dateModified\":\"2025-02-24T02:24:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png\",\"contentUrl\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png\",\"width\":600,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/product\\\/microfluidic-chip\\\/organ-chip\\\/1407\\\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\\\/\\\/www.dxfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7c7b\u5668\u5b98\u82af\u7247\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/\",\"name\":\"\u9876\u65ed\u5fae\u63a7\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dxfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#organization\",\"name\":\"\u9876\u65ed\u5fae\u63a7\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/logo.jpg\",\"contentUrl\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/logo.jpg\",\"width\":500,\"height\":500,\"caption\":\"\u9876\u65ed\u5fae\u63a7\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/#\\\/schema\\\/person\\\/255c77b7dba4089ee0f61539d31afbf7\",\"name\":\"dxfluidics\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/\u5546\u6807.png\",\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/\u5546\u6807.png\",\"contentUrl\":\"https:\\\/\\\/www.dxfluidics.com\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/\u5546\u6807.png\",\"caption\":\"dxfluidics\"},\"description\":\"\u9876\u65ed\uff08\u82cf\u5dde\uff09\u5fae\u63a7\u6280\u672f\u6709\u9650\u516c\u53f8\u662f\u4e00\u5bb6\u4e13\u6ce8\u4e8e\u5fae\u6d41\u63a7\u9886\u57df\u7684\u9ad8\u79d1\u6280\u4f01\u4e1a\uff0c\u6211\u4eec\u81f4\u529b\u4e8e\u4e3a\u5ba2\u6237\u63d0\u4f9b\u5fae\u6d41\u63a7\u82af\u7247\u5b9a\u5236\u3001\u8868\u9762\u4fee\u9970\u6539\u6027\u3001\u5fae\u6d41\u63a7\u82af\u7247\u52a0\u5de5\u8bbe\u5907\u3001\u4ee5\u53ca\u5fae\u6d41\u63a7\u4eea\u5668\u7b49\u5168\u9762\u7684\u5fae\u6d41\u63a7\u89e3\u51b3\u65b9\u6848\u3002\u516c\u53f8\u56e2\u961f\u62e5\u6709\u4e30\u5bcc\u7684\u7ecf\u9a8c\u548c\u6280\u672f\u79ef\u7d2f\uff0c\u6301\u7eed\u5c06\u4e13\u4e1a\u77e5\u8bc6\u4e0e\u521b\u65b0\u601d\u7ef4\u76f8\u7ed3\u5408\uff0c\u4e3a\u5ba2\u6237\u63d0\u4f9b\u9ad8\u54c1\u8d28\u7684\u89e3\u51b3\u65b9\u6848\u3002\u6211\u4eec\u5c06\u59cb\u7ec8\u575a\u6301\u4ee5\u5ba2\u6237\u4e3a\u4e2d\u5fc3\uff0c\u4e0d\u65ad\u6311\u6218\u81ea\u6211\uff0c\u4e0d\u65ad\u8ffd\u6c42\u5353\u8d8a\uff0c\u901a\u8fc7\u4e13\u4e1a\u3001\u521b\u65b0\u548c\u5408\u4f5c\uff0c\u4e3a\u5ba2\u6237\u521b\u9020\u66f4\u5927\u7684\u4ef7\u503c\uff0c\u5171\u540c\u5f00\u521b\u5fae\u6d41\u63a7\u9886\u57df\u7684\u7f8e\u597d\u672a\u6765\u3002\",\"sameAs\":[\"https:\\\/\\\/www.dxfluidics.com\"],\"url\":\"https:\\\/\\\/www.dxfluidics.com\\\/en\\\/author\\\/dxfluidics\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dxfluidics.com\/en\/product\/microfluidic-chip\/organ-chip\/1407\/\u7c7b\u5668\u5b98\u82af\u7247\/","og_locale":"en_US","og_type":"article","og_title":"\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7","og_description":"\u53cc\u6d41\u9053\u8bbe\u8ba1\u7c7b\u5668\u5b98\u82af\u7247 \u4e00\u6b3e\u5148\u8fdb\u7684\u7c7b\u5668\u5b98\u82af\u7247\u6280\u672f\uff0c\u5176\u8bbe\u8ba1\u7075\u611f\u6765\u6e90\u4e8e\u7c7b\u5668\u5b98\u82af\u7247\u7684\u7406\u5ff5\uff0c\u5b83\u7531\u4e24\u4e2a\u72ec\u7acb\u901a\u9053\u7ec4\u6210\uff0c\u652f\u63012 [&hellip;]","og_url":"https:\/\/www.dxfluidics.com\/en\/product\/microfluidic-chip\/organ-chip\/1407\/\u7c7b\u5668\u5b98\u82af\u7247\/","og_site_name":"\u9876\u65ed\u5fae\u63a7","article_published_time":"2023-10-23T01:30:45+00:00","article_modified_time":"2025-02-24T02:24:08+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png","type":"image\/png"}],"author":"dxfluidics","twitter_card":"summary_large_image","twitter_misc":{"Written by":"dxfluidics","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#article","isPartOf":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/"},"author":{"name":"dxfluidics","@id":"https:\/\/www.dxfluidics.com\/#\/schema\/person\/255c77b7dba4089ee0f61539d31afbf7"},"headline":"\u7c7b\u5668\u5b98\u82af\u7247","datePublished":"2023-10-23T01:30:45+00:00","dateModified":"2025-02-24T02:24:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/"},"wordCount":18,"publisher":{"@id":"https:\/\/www.dxfluidics.com\/#organization"},"image":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png","articleSection":["\u7ec6\u80de\u82af\u7247\/\u5668\u5b98\u82af\u7247"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/","url":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/","name":"\u7c7b\u5668\u5b98\u82af\u7247 - \u9876\u65ed\u5fae\u63a7","isPartOf":{"@id":"https:\/\/www.dxfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#primaryimage"},"image":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png","datePublished":"2023-10-23T01:30:45+00:00","dateModified":"2025-02-24T02:24:08+00:00","breadcrumb":{"@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#primaryimage","url":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png","contentUrl":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2023\/10\/\u7ec6\u80de\u57f9\u517b\u82af\u7247-09-1.png","width":600,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.dxfluidics.com\/product\/microfluidic-chip\/organ-chip\/1407\/%e7%b1%bb%e5%99%a8%e5%ae%98%e8%8a%af%e7%89%87\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.dxfluidics.com\/"},{"@type":"ListItem","position":2,"name":"\u7c7b\u5668\u5b98\u82af\u7247"}]},{"@type":"WebSite","@id":"https:\/\/www.dxfluidics.com\/#website","url":"https:\/\/www.dxfluidics.com\/","name":"DXFLUIDICS","description":"","publisher":{"@id":"https:\/\/www.dxfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dxfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.dxfluidics.com\/#organization","name":"DXFLUIDICS","url":"https:\/\/www.dxfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dxfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2024\/04\/logo.jpg","contentUrl":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2024\/04\/logo.jpg","width":500,"height":500,"caption":"\u9876\u65ed\u5fae\u63a7"},"image":{"@id":"https:\/\/www.dxfluidics.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.dxfluidics.com\/#\/schema\/person\/255c77b7dba4089ee0f61539d31afbf7","name":"dxfluidics","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2022\/09\/\u5546\u6807.png","url":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2022\/09\/\u5546\u6807.png","contentUrl":"https:\/\/www.dxfluidics.com\/wp-content\/uploads\/2022\/09\/\u5546\u6807.png","caption":"dxfluidics"},"description":"DingXu (Suzhou) Microfluidics Technology Co., Ltd. is a high-tech enterprise dedicated to the field of microfluidics. We are committed to providing customers with comprehensive microfluidic solutions, including customized microfluidic chip development, surface modification, microfluidic chip processing equipment, and microfluidic instruments. Our team boasts extensive experience and technical expertise, continuously combining professional knowledge with innovative thinking to deliver high-quality solutions. We consistently prioritize customer-centric values, embrace self-challenges, and pursue excellence. Through professionalism, innovation, and collaboration, we aim to create greater value for our customers and contribute to a brighter future in the field of microfluidics.","sameAs":["https:\/\/www.dxfluidics.com"],"url":"https:\/\/www.dxfluidics.com\/en\/author\/dxfluidics\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/posts\/1407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/comments?post=1407"}],"version-history":[{"count":1,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/posts\/1407\/revisions"}],"predecessor-version":[{"id":3771,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/posts\/1407\/revisions\/3771"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/media\/1408"}],"wp:attachment":[{"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/media?parent=1407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/categories?post=1407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dxfluidics.com\/en\/wp-json\/wp\/v2\/tags?post=1407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}